Troubleshooting Pralson Feeders | 5 Quick Fixes
Sep 25, 2026
  • Automatic poultry feeding systems increase farm operational profitability.

  • Engineering feed line troubleshooting protocols restores nominal volumetric output.

  • Equipment precision calibration prevents transmission gear mechanical stress.

  • Diagnostic power supply procedures reduce costly motor downtime losses.

  • System line voltage stability guarantees high flock uniformity rates.

Get professional poultry farm construction guidance, equipment selection solutions, and the latest price lists. 

Please contact us, WhatsApp NO. : +8613582487372, click to learn more.

Taiyu (HK) Group Equipment

Taiyu (HK) Group Equipment



Primary Fault Diagnostic Protocol



As a global leader in poultry equipment manufacturing, we design precise, high-durability automated feeding solutions engineered to deliver up to 45 kg/min flow capacity while maintaining a targeted feed conversion ratio (fcr) of 1.45–1.55.

However, even commercial systems operating at 1420 rpm motor speeds encounter mechanical, electrical, or flow-rate irregularities due to dust concentrations exceeding 15 mg/m³, ambient humidity up to 85%, or component operational fatigue beyond 12,000 hours.

To help farm managers maintain an uninterrupted feed supply across 150-meter line runs and safeguard flock uniform growth rates above 92%, our engineering team has synthesized this field-tested technical diagnostic manual.

Below are five critical diagnostic protocols, structured root-cause analyses, and engineered remediation procedures for pralson feeders.

Data is for reference only. Swipe horizontally to view full table.

Fault Code CategoryVisual & Acoustic IndicatorsPrimary System ImpactInitial Diagnostic StepRecommended Service Action
FL-01: Line StallsMotor humming; shaft speed 0 Rpm; thermal trip at 135°cComplete feed stoppage across 300 down-spoutsMeasure line voltage under load (380–415 v)Reset relay; clear packed mash feed exceeding 650 kg/m³ bulk density
FL-02: Uneven DeliveryEnd-line pan feed depth < 5 mm; drive end pans > 35 mmFlock body weight variance exceeding ±12%Check capacitive sensor sensing gap at 8.0 mm ± 0.5 mmRecalibrate sensor potentiometer; clean 0.5 mm dust layer from lens
FL-03: Bridging / CloggingHopper motor drawing 3.8 a; auger running empty at 280 rpmFeed delivery drop below 2.5 kg/min per panInspect boot throat clearance set at 25.0 mmAdjust hopper boot slide gate to notch position 4 (40.0 mm opening)
FL-04: Excess WearNoise level > 85 dba; line housing vibration > 4.5 mm/sConveying pipe wall thickness reduction below 1.8 mmMeasure tube sagging pitch exceeding 18.0 mm per dropRe-tension suspension cables to 450 n; replace drive bushings
FL-05: Electrical FaultControl board supply voltage 0 v Ac; status leds unlitLoss of 24-hour automated feeding timer controlTest 24 v ac transformer secondary winding outputReplace blown 2.0 a fast-blow fuse; torque terminal screws to 1.2 n·m



Motor Drive Unit Malfunctions & Torque Loss



Core system powertrain analysis

The 0.75 kw motor drive assembly serves as the core powertrain for pralson flexible auger feed lines operating under line tension loads up to 1800 n.

Electrical & operational thresholds

Mechanical overload or voltage fluctuations beyond ±7% can trigger internal protection mechanisms or cause physical drive key shearing.

Diagnostic workflow & engineering specifications

Electrical input verification: utilize a calibrated digital multimeter to verify line voltage across all active phases (230 v ± 11.5 v single-phase or 400 v ± 20 v three-phase, 50/60 hz ± 1.5 hz).

Voltage drops exceeding 28 v under starting current surges of 18 a indicate undersized electrical supply cabling below 2.5 mm² cross-section or loose terminal block contacts.

Gearbox & sheave inspection: disconnect main power.

Inspect the direct-drive 10:1 ratio gearbox for lubricant leaks or axial end-play in the output shaft exceeding 0.15 mm.

Pralson gearboxes utilize synthetic oil with a kinematic viscosity of 220 cst at 40°c; fluid levels falling below 350 ml induce metal-on-metal friction.

Auger tension calibration: disengage the drive shaft coupling.

Rotate the drive shaft manually using a 0–50 n·m torque wrench.

Breakaway resistance exceeding 22 n·m on a standard 120-meter line indicates internal tube binding or compacted pellet feed accumulation.



Auger Conveying Assembly Specifications



Data is for reference only. Swipe horizontally to view full table.

Component PartMaterial SpecificationTolerances & Wear LimitsFailure IndicationCorrective Maintenance Standard
Conveying TubeUv-stabilized rigid pvc / Galvanized steelOuter diameter: 45.0 mm ± 0.15 mm; wall: 3.2 mmTube wall thickness drop below 1.5 mmInstall 150 mm stainless sleeve couplers torque-tightened to 8 n·m
Flexible AugerHigh-tensile carbon steel (1400 mpa)Flat wire pitch: 38.5 mm ± 0.5 mm; outer dia.: 36.2 mmPermanent extension exceeding 240 mm per 100 m runTrim extended auger length by 250 mm; re-clamp with 35 n·m torque
Drive ShaftHardened alloy steel (42crmo₄)Shaft runout: < 0.03 mm; keyway width: 6.00 mm +0.03 mmKeyway deformation exceeding 0.20 mmReplace drive shaft; install 6 mm × 6 mm × 30 mm hardened keyway steel
Suspension ClampsHeavy-duty galvanized steel (2.0 mm)Mounting spacing: 2500 mm ± 50 mm center-to-centerHorizontal deviation exceeding 12.0 mmRe-torque suspension clamp bolts to 14 n·m; level line to ±2.0 mm
Drive BushingsSelf-lubricating nylon 66 with 15% ptfeInternal diameter: 25.4 mm +0.10 mm; length: 45 mmRadial inner clearance expansion beyond 1.20 mmReplace worn bushing; re-apply synthetic silicone grease (1.5 g)


Control Pan Proximity Sensor Calibration



Automated poultry feeding equipment relies on an end-control pan capacitive proximity sensor operating at 24 v dc to toggle the 3-phase contactor coil automatically.

Dust accumulation, moisture levels exceeding 75% rh, or physical tilt angles greater than 5° can alter capacitive field sensitivity.

Calibration steps & sensitivity adjustment

Clear optical & capacitive sensing surfaces power down the system main switch.

Wipe the sensor head using an isopropyl alcohol wipe (99.8% purity) to remove residual oil, organic dust, and particle crusts.

Coarse sensitivity setting: located on the rear of pralson capacitive sensors is a 20-turn precision potentiometer.

Turn the potentiometer counter-clockwise for approximately 8–10 full revolutions until the red led indicator extinguishes while the pan feed level is at 0 mm.

Fine sensitivity calibration: fill the control pan with standard feed pellets (3.5 mm diameter) to a precise depth of 20.0 mm.

Turn the potentiometer clockwise at a rate of 0.5 turns/sec until the led illuminates, then advance an additional 90° clockwise rotation to ensure reliable triggering across feed moisture variations between 9.5% and 13.5%.

Time-delay logic verification: ensure the internal digital off-delay timer potentiometer is dialed to 20 seconds ± 2 seconds.

This prevents rapid motor short-cycling when bird activity causes transient feed displacement.



Feed Flow Rate and Boot Interface Dynamics



Data is for reference only. Swipe horizontally to view full table.

Interface ParameterStandard Operating RangeDeviational Root CauseImpact on SystemEngineering Solution
Boot Intake GateGate gap: 15.0 mm to 45.0 mmLock pin displacement by 10.0 mmFlow rate error exceeding ±25%Re-position indicator pin to notch 3 (30.0 mm gap setting)
Feed Moisture ContentRelative moisture: 10.5%–12.0%Relative humidity inside silo > 82%Feed compaction force exceeding 45 kpaTurn on 0.25 kw hopper agitator; clear caked feed mass
Agitator ClearanceGap distance: 3.0 mm–4.5 mmFastener slip under 12 n·m back-torqueAgitator resistance torque > 8.5 n·mRe-center agitator blade; torque grade 8.8 locking bolts to 18 n·m
Boot Shaft SealNbr rubber seal (type AS 25 × 40 × 7 mm)Dust particle abrasion > 50 μm sizeFeed dust ingress into bearing cavity > 5 g/hrReplace nbr lip seal; pack bearing housing with 10 g lithium grease
Drop Tube AngleVertical orientation: 90° ± 1.5°Suspension drop wire offset by > 35 mmUnbalanced lateral feed force > 15 nAdjust drop cable grippers to restore perpendicular alignment to 90.0°



Electrical Control Panel Diagnostics



Pralson automated control panels integrate 10 a miniature circuit breakers, 12 a magnetic contactors, and digital control modules to manage feeding cycles across ambient operating temperatures from −10°c to +55°c.

Control StepPrimary VerificationDiagnostic ConditionEngineering Operational Standard
Step 1Control voltage outputConfirm transformer supply voltage24.0 v ac ± 0.5 vacross terminals x1 and x2 (0.85 a load)
Step 2Voltage degradationMonitor contactor chatter thresholdsControl voltages dropping below 21.5 v ac cause pitting > 0.3 mm
Step 3Overload relay statusReset indicator on thermal overloadThermal relay set point calibrated at 2.1a–2.5 a
Step 4Phase winding testMicro-ohmmeter resistance across leadsResistance balanced within 14.2 Ω ± 0.3 Ω at 20°c
Step 5Sensor bypass testJumper terminals t3 and t4Contactor pulls in within 50 ms to confirm control logic

Executing these systematic isolation procedures ensures accurate electrical troubleshooting across all automated feed lines.



Feed Pan Height and Anti-Roost Tensioning



Data is for reference only. Swipe horizontally to view full table.

Line ParameterBrooder Phase (Days 1–14)Growing Phase (Days 15–28)Finishing Phase (Day 29+)Adjustment Mechanism
Pan Lip Elevation0.0 mm (rests on litter)120.0 mm ± 10.0 mm280.0 mm ± 15.0 mmCentral ceiling winch (1500 kg rated capacity)
Anti-Roost Voltage0 v ac (system de-energized)900 v ± 50 v pulsed dc1400 v ± 50 v pulsed dcPralson electric fence controller (0.5 J)
Suspension Cable SagMaximum 3.0 mm per 10 m runMaximum 5.0 mm per 10 m runMaximum 7.0 mm per 10 m runManual drop wire turnbuckles (M6 × 100 mm)
Pan Cone Level SlotPosition 1 (45 mm cone gap)Position 3 (30 mm cone gap)Position 5 (15 mm cone gap)Rotating cone selector collar with 5 locking detents
Horizontal AlignmentDeviation < ±2.0 mm per 20 mDeviation < ±4.0 mm per 20 mDeviation < ±5.0 mm per 20 mStainless steel line adjustment clamps (38.1 mm)


Preventative Maintenance Schedules



Establishing regular scheduled maintenance routines extends automatic feeder lines operational life to over 15 years and preserves mechanical transmission efficiency above 91%.

Daily system checks: perform visual inspection of control panel voltage displays (380–415 v) and record daily running current (1.8–2.4 a).

Listen for high-frequency acoustic emissions above 78 dB at 1.0 meter distance along the conveying line.

Ensure the control pan inner base remains free of packed organic debris exceeding 2.0 mm thickness.

Flock turn-around maintenance (between batches): Isolate system power using 32 a main rotary switch; wash feed pans with water pressure restricted below 25 bar to protect Ip65 seal integrity.

Measure flexible auger free elongation; cut and re-clamp augers showing permanent elongation exceeding 120 mm per 50-meter section.

Inspect all 3.0 mm stainless steel suspension cables and 45 mm galvanized pulleys for individual wire breaks exceeding 2 wires per strand.

Annual comprehensive overhaul: drain and refill gearbox oil using 450 ml of synthetic Iso vg 220 gear lubricant.

Measure internal wall wear on pvc tubes; replace pipe lengths where wall thickness has decreased from 3.2 mm to below 2.0 mm.

Recalibrate thermal overload trip response times to ensure cutoff within 4.0 seconds at 300% rated current (6.6 a).



Wear Component Lifetime Limits



Data is for reference only. Swipe horizontally to view full table.

Equipment ComponentExpected Operating LifeWear Limit CriteriaReplacement Trigger PointRecommended Spare Stock Level
Flexible Carbon Auger18,000 hours (25 batches)Pitch expansion > 42.0 mmOuter diameter wear below 34.5 mm1 roll (100 meters) per 4 lines
Pvc Conveying Tubes25,000 hoursBottom wall wear > 1.6 mmTube structural flexure > 25 mm/m12 pipe sections (3.0 meters each)
Proximity Sensors12,000 hoursSignal delay shift > 1.5 secInternal circuit resistance > 500 Ω2 sensor units per house
Motor Contactors150,000 cyclesContact erosion depth > 0.4 mmPole phase imbalance > 5.0 v2 contactors (24 v ac coil)
Drive Shaft Seals8,000 hoursLip clearance wear > 0.35 mmGearbox oil leak rate > 1 ml/day6 nbr double-lip seals


Auger Tube Alignment & Structural Rigidity



Maintaining exact axial alignment along poultry feed line hardware minimizes internal parasitic friction losses, reducing total power consumption from 750 w down to 580 w during continuous operation.

Alignment & structural rigidity protocol

Laser line sighting mount a 635 nm red line laser at the drive unit bracket and project the beam along the line to the hopper boot target.

Total horizontal and vertical alignment offset across a 150-meter feeder line run must be held within a strict tolerance band of ±6.0 mm.

Suspension drop wire tensioning verify drop wires are positioned at intervals of 2500 mm.

Use a digital cable tension meter to verify each 3.0 mm steel cable maintains a static tension of 220 n ± 15 n.

Cable tension variations greater than 50 n introduce localized pipe bending that elevates motor starting torque requirement to over 38 n·m.

Expansion joint positioning in houses experiencing temperature variations from 15°c to 40°c, thermal linear expansion of pvc lines reaches 2.1 mm/meter.

Install telescoping expansion couplings every 45 meters to absorb linear dimensional movements up to 95 mm without pipe buckling.



Feed Pan Component Wear & Flow Efficiency



Data is for reference only. Swipe horizontally to view full table.

Pan Assembly ComponentFunctional RoleInspection MethodDamage ConsequenceCorrective Action
Adjustment CollarSets vertical cone gap (10 mm–50 mm)Vernier caliper depth measurementCone gap drift exceeding ±6.0 mmReplace worn locking collar detent clip
Anti-Spill Pan RimReturns feed back to pan centerInner lip angle gauge (22° ± 1°)Daily feed wastage exceeding 15 g/panReplace pan bottom tray (120 g virgin pp)
14-Spoke GrillPrevents bird entry into pan centerTensile force test (150 n push limit)Strut gap expansion beyond 48.0 mmSnap in replacement 14-spoke grill assembly
Drop Tube Slide GateShuts off feed to specific pansSliding force gauge (15 n–25 n)Material bypass rate > 50 g/min when closedClean gate tracks; replace distorted slide plate
Suspension HookSecures pan to 45 mm conveying pipeInclinometer tilt check (0° ± 1°)Pan tilt angle > 4°; uneven feed depthRe-center hook on pipe alignment ridge


Complete Equipment Support & Ordering Genuine Parts



Maintaining operational reliability across commercial poultry farm feeders requires genuine oem replacement components manufactured to original Pralson engineering tolerances.

Non-standard aftermarket parts can increase mechanical friction by up to 30%, reduce component service life by 50%, and void the standard 3-year factory warranty covering drive powertrains.

Our technical service network provides global support coverage with guaranteed dispatch times under 24 hours for primary service components, complete engineering schematics, and remote diagnostic assistance.

The average emergency dispatch fee is approximately $250 usd (European union standard reference only).



Why Choose Genuine Pralson OEM Components?



Precision-matched tolerances our high-tensile carbon steel augers are manufactured with a surface finish roughness of ra 0.8 μm and engineered to operate inside pralson pvc tubes with a radial clearance of 1.9 mm ± 0.1 mm, lowering electrical power draw by 160 watts.

Agricultural-grade polymers all plastic pan structures are molded using virgin polypropylene containing 2.5% uv-inhibitor additives, engineered to sustain impact forces of 12.0 kj/m² at 0°c and withstand cleaning solution concentrations up to 5% active chlorine.

Factory warranty assurance every genuine pralson drive assembly, proximity switch, and conveying tube section comes backed by our direct manufacturer replacement guarantee and Iso 9001:2015 quality compliance certification.

For direct technical assistance, spare parts catalog requests, or to schedule an on-site system audit with an engineering specialist, contact your regional authorized pralson equipment dealer or access our technical portal today.

Keep your farm operating at peak production efficiency with pralson the precision engineered standard in modern poultry production infrastructure.



Frequently Asked Questions



Q1: How do I troubleshoot a line stall on pralson feeders?

A1: Check line voltage stability between 380 v–415 v and inspect the 0.75 kw drive unit thermal overload relay set at 2.1 a–2.5 a to clear packed feed density exceeding 650 kg/m³.

Q2: Why is feed distribution uneven across my pralson feeders?

A2: Inspect the end-line 24 v dc proximity sensor gap set at 8.0 mm ± 0.5 mm, clean organic dust layers exceeding 0.5 mm, and verify off-delay logic timer set to 20 seconds.

Q3: How often should I adjust anti-roost tension on pralson feeders?

A3: Monitor line sag parameters under 3.0 mm per 10 m run during brooding and maintain pulsed dc voltage output at 1400 v ± 50 v during finishing stages.



Taiyu (HK) Group - One Of China Most Famous Pralson Feeders Manufacturer



  • Pralson feeders feature a 0.75 kw drive assembly engineered to deliver up to 45 kg/min flow capacity across 150-meter runs with a feed conversion ratio of 1.45–1.55.

  • We operate as a direct global factory direct sales entity delivering factory-direct pricing without distributor markups.

  • Our comprehensive commercial poultry equipment production lines comply with global Iso 9001:2015 manufacturing standards.

  • We deliver complete turn-key engineering solutions including system design, electrical control integration, and on-site commissioning.

  • Our worldwide technical network provides full life-cycle equipment support, emergency spare parts dispatch, and farm installation services.



Contact Us To Received Your Customized Poultry Farm Plan



Headquarters And Branchs

poultry farm

Hong Kong Headquarter Management Team


  • Hong Kong Headquarter Taiyu Industrial Group CO., LTD

  • China Hebei Best Machinery And Equipment CO., LTD

  • Nigeria Vanke Machinery And Equipment CO., LTD

  • Tanzania Best Machinery And Equipment CO., LTD

  • Ethiopia Best Hebei Machinery Manufacturing PLC


supplier and manufacture chicken cage and poultry farm equipment (2)

China Branch


supplier and manufacture chicken cage and poultry farm equipment (3)

Nigeria Branch


supplier and manufacture chicken cage and poultry farm equipment (4)

Tanzania Branch


chicken cage design (1)

Ethiopia Branch


Reception /24 online WhatsApp NO. : +8613582487372

Email: managerwang@bestpoultryfarm.com